Autodesk Vault 2019
Products
26th March 2018
This file contains information that became available prior to
releasing Autodesk Vault 2019 or that you will find useful while using
Autodesk Vault 2019.
For the latest version of this file please see the
Autodesk Vault Products Release Notes Page
System Requirements for all Vault products are accessible
through the Vault install and www.autodesk.com/vault-system.
DISCLAIMER: Migrating data from a Beta
product to the released product is not supported.
Vault Server
Install Information
- If you have previous Beta Vault products installed on your
machine,
you will need to uninstall them prior to installing this release.
- Uninstall the client software from all machines.
- Open the Beta ADMS Console.
- Delete all vaults and libraries.
- Delete the master vault.
- Uninstall ADMS. (please close Vault Client and Server,
before initiating the Uninstall command)
- Autodesk Vault 2019 installs .NET 4.7 to your operating
system.
Further, Vault 2019 requires ASP.NET 4.6 be enabled when installing IIS
on ADMS. If you encounter an error during ADMS installation, go to
Start > Control Panel > Programs > Turn Windows
features on or
off > .NET Framework 4.6 Advanced Services and enable ASP.NET
4.6.
- To avoid potential install failure when installing Autodesk
Vault
2019, make sure the following Microsoft updates are installed on your
machine before starting the installation: Windows 2012 R2: KB2919442;
KB2919355; KB4019990
SQL Server
Install Information
- Vault Server installation installs SQL Express 2014 SP2
(64-bit).
- An issue has been discovered with SQL access after .NET 4.6
has
been installed on the same machine. The issue found is that the Vault
Server will be unable to connect to the SQL Database Engine using the
TCP protocol when the Vault Server and the SQL database engine are
installed on the same machine. Until a Microsoft fix is available, it
is recommended that you edit the protocol priority in the SQL
Configuration manager. In the manager, place Shared Memory first
followed by TCP then Named Pipes. Make sure that Shared Memory protocol
is enabled for this to work properly.
- When installing Vault Server using Local Language on Local
O/S, the
following message may appear: "This SQL Server setup media does not
support the language of the OS, or does not have the SQL Server
English-language version installation files. Use the matching
language-specific SQL Server media; or install both the language
specific MUI and change the format and system locales through the
regional settings in the control panel." Reference Microsoft
Link for more information.
- When using SQL Server 2014, SQL 2016 or SQL Server 2017,
all
databases must
remain at the SQL 2012 compatibility level. New databases created using
the Vault Server Console will be set for 2012 compatibility level
automatically.
- Installing SQL onto a computer that has the Program Files
folder compressed is not supported and will cause the install to hang.
Migration -
Working with Legacy Vault Data
| Supported Migration
Versions |
Vault Basic
2017
Vault Workgroup 2017
Vault Professional 2017 |
Vault Basic
2018
Vault Workgroup 2018
Vault Professional 2018
|
- If you are migrating from any previous release, Autodesk
strongly
encourages reviewing and understanding the README of each version of
Vault being skipped, including this README.
- When migrating large vaults, there may be a long delay
before the
progress dialog is shown. The delay can exceed 10 minutes depending on
the configuration of the vault.
- Migrating from one OS to another OS when OS formatting
(Regional
Settings) is different between the two is NOT supported. Prior to
upgrading to Vault 2019, OS formatting on the target server must be
changed to match that of the originating server.
- When performing an in-place upgrade from previous releases
of Vault
with Content Center Libraries, the existing Content Center Libraries
must be migrated prior to installing the new Content Center Libraries.
Vault
Server Information
- Property indexing for AutoCAD file types may not work if
the AutoCAD based product is installed on the same machine as the Vault
Server. If indexing problems are encountered, a repair on the ADMS
Console installation should resolve the issue.
- There are some instances whereby the Content Index Service
does
not work after an Upgrade/Migration has been performed. Ensure that the
Autodesk Job Dispatch Service is restarted and running after an
Upgrade/Migration has been performed.
- When the Vault Server and Vault Client are installed on the
same
x64 machine, the Client should be installed after the Vault Server
install. Otherwise certain Vault client operations (e.g.,
Batch
Plot, Update View) may result in an error.
- In order to view PDF thumbnails an iFilter must be
installed on the
server. A PDF viewer such as PDF-Xchange Viewer may be used to enable
PDF thumbnails. Additional viewers should be installed after Adobe
Reader on the server machine. A reboot and re-index of File Properties
is also required after installing the viewer(s).
Return to
Top
Vault
Client Install Information
- Vault 2019 products no longer support 32-bit versions of
Windows 7, Windows 8, Windows 8.1 and Windows 10 operating systems.
- To avoid potential install failure when installing Autodesk
Vault
2019, ensure following Microsoft updates are already exist on your
machine before starting the installation:
- Windows7: KB 2533552; KB4019990
- Windows 8.1/Windows 2012 R2: KB2919442; KB2919355;
KB4019990
- Autodesk Vault 2019 installs .NET 4.7 on your operating
system. If
you encounter any error during .Net 4.7 installation, reboot your
machine and try the installation again. Refer to Microsoft Support Page
Known
issues for the .NET Framework 4.7 for more information.
- Before installing the Vault 2019 client, be sure to
uninstall all
Beta versions of Vault components including InventorView, DWG TrueView,
etc.; otherwise the correct versions of these components may not
install properly. Note you need to close the applications before
initiating Uninstall command.
- Installation
of New Autodesk Design Review with Vault Client 2019 will be blocked by
the old version of the Autodesk Design Review found on the same
machine. We strongly recommend you to uninstall the old Autodesk Design
Review before installing Vault Client 2019.
- The Job Processor
and Copy Design 2019 shortcuts in Start Menu\Programs\Autodesk\Tool are
not removed with Vault Client 2019 uninstallation, if user has Vault
Clients for multiple releases or editions installed on the machine.
User can delete these shortcuts manually.
- Vault Installer UI will close when switching from install
mode to deployment mode.
Vault
Client Information
All Vault Editions
- Copy Design
- The version of Inventor last run on your machine will be
used for operations run using the Vault Client, such as Copy Design. If
the last run version of Inventor is older than the version of the files
you are changing through the Vault client, then the Vault client will
display an error. For example, if you last ran Inventor 2018 on your
computer and try to do a Copy Design on files last saved in Inventor
2019, Copy Design will fail.
- Copy Design on a substitute part results in the new part
referencing the original derived assembly.
- When using Copy Design on an assembly that uses derived
components,
if you attempt to change the master sketch on one file, it will replace
the master sketch on all files referencing the master sketch. It is
recommended that you copy all instances. Copying one derived part but
reusing another referencing the same master sketch is not supported.
Vault
Workgroup and Vault Professional Editions
- Publish PDF from 2D CAD Files
- AutoCAD files linked as Overlay/Attached (Xref content)
may not
appear in 2D PDF after rename of the drawing file if the child file
type is Microstation DGN.
- Publish PDF from 2D CAD Files of the same name (e.g.
drawings named
identical but stored in different folders) will result in the second
PDF file overwriting the first PDF file when the Administrator
specifies a single destination folder for all newly generated PDF files.
- Synchronization of the drawing and 2D PDF files'
properties and
revisions may fail which will result in 2D PDF files that have no
attachment link to their parent drawing file. Properly synchronizing
the files and creating the attachment links will require manual
intervention by your Vault administrator.
- Vault may not break the attachment link as expected
between a new
drawing file revision and a prior 2D PDF revision when Vault creates
the new drawing revision (e.g. if configuration of Publish 2D PDF is
disabled before the creation of the next drawing revision). Breaking
these links will require manual intervention by your Vault
administrator.
- Drawings with 2D PDF files attached manually lose the
attachment
link to the original 2D PDF when Vault publishes a new 2D PDF for that
drawing.
- Manual revision of a 2D PDF attached to a non-revisioned
drawing
(e.g. modified via Quick Change) will result in failures when
synchronizing their file properties and revisions.
- Migrated vaults from a prior Vault version to Vault 2019
will not
have the predefined Category, Rule, and default State to process
publishing PDFs from 2D CAD files. Manual configuration is required for
these vaults.
- Administrative publishing options and lifecycle actions
for Publish
PDF from 2D CAD Files will not be available using prior version Vault
clients but the related Category and Lifecycle will appear.
- AutoCAD LT and Inventor LT
- Update view is not supported with Inventor LT. This
includes jobs sent to a Job Server on a machine running Inventor LT.
- Revision table functionality for assemblies is not
supported with
Inventor LT. This includes jobs sent to a Job Server on a machine
running Inventor LT.
Vault
Professional Edition Only
- Properties
- A custom UDP for an Inventor DWG cannot be mapped to an
Item Entity
Type. The workaround is to create and map the UDP to a File Entity
Type, and then change the File Entity type to an Item Entity type.
- Items
- Updating an item will only update the unpinned file
attachment
versions for the item being updated. Any child items being updated as a
result will not have their file attachment versions updated. You will
need to update those items individually.
- For ACADM BOM rows that are merged, the group icon is
not displayed. Instead the item icon is shown.
- For rows that are added manually, the units of measure
won’t
change automatically if the item’s units are changed after the row was
added. As a workaround, those rows have to be removed and added again
to show the current units of measure of the item.
- BOM Reports are always off the top level of BOM tab.
Hence it is not right-click context menu sensitive.
- BOM Reports does not support thumbnail.
- While an item is at pending creation state, 'Assign To'
is not
allowed to another existing item of Released state. As a workaround,
turn off the row and perform Assign To again.
- Configuration factories (iFactory) cannot be assigned to
items.
However, the error message that appears when performing Turn Row On,
Turn Branch On, or Assign To on configuration factories, is not
accurate. Checking out and checking the file back in will not work in
this case even though that’s what the error message suggests. A member
of the factory must be used in place of the factory in order for the
component to be promoted to an item.
- Sometimes the setting Group BOM rows as per the design
BOM is not
honored especially when Part Numbers are modified after the components
have been inserted. If this happens, check out the assembly, uncheck
the checkbox for the BOM setting, Enable Row Merge on Part Number
Match, check it back again, save the assembly, check it into Vault and
update the item.
- Vault doesn’t allow inserting an item into the same item
(due to
circular reference restriction). And when a user tries to assign item
to a parent file that has a child with the same equivalence value,
Vault displays a circular reference error. However, in some cases,
instead of displaying this error message, Vault makes the child file a
secondary link to the existing parent item. To get out of this
situation, edit the parent item, remove the secondary link for the
child, save the item, turn off the option “Auto-select first duplicate
item," and update the parent item. The child should now have a new item
assigned to it.
- ‘Assign/Update Item’ from file only updates the related
item if the
file has been modified since the last item assignment or update. If the
file has not been modified, it is possible that items may be created
for BOM children but the root item is not updated to include these new
items. The solution to this is to ‘Update’ the item itself (from the
item view) – this forces the item to be updated regardless of whether
the file itself has changed.
- Item update may fail and result in Error 1455 or item
links
remaining stale on old data where vault edits have versioned the file.
To resolve this, version the file through the CAD application and
perform the item update again.
Return to
Top
AutoCAD
Add-in Information
- Files with point cloud attachments are not supported. If
checked in, the file will lose its association to the point cloud
attachment.
- Image reference of a DWG file will not be loaded correctly
if the DWG file had been moved.
- Creating a New Part reference via Open from Vault will not
update
the Parts list if the Part Reference is not available in the part list
already.
- Refresh an Electrical project file (wdp) may not download
the
related configuration files. Use Open Project from Vault to download
the newer or missing configuration files.
- After Electrical files are renamed in the Vault client or
with the
new Copy Design, invoking "Refresh All Files" with the AutoCAD
Electrical addin causes an unexpected exit. Use Open Project from Vault
instead of Refresh All Files to get the newer files.
- Thumbnail
generation may fail for certain AutoCAD dwg files.
Folder
Check In
- The following methods may be used with Folder Check In on
large folders if problems occur:
- Add sub-folders individually. To do this, first break
down the main
folder into sub-folders, then set the working folder to the top most
folder. This will maintain the folder structure and file relationships
after check-in.
- Increase the number of GDI handles, visit the Microsoft GDI
Handles article for instructions. Seek assistance from your
Administrator if you are not familiar with Windows Registry settings.
- The following are restrictions on Folder Check In of DXF
files from within AutoCAD based products:
- DXF files with attachments cannot be checked into the
Vault (be it within or outside the working folder).
- Only single DXF files without attachments can be checked
into the
Vault if they are placed within the working folder. The user will be
prompted to save the DXF file upon every Check-in.
- DXF files will not be checked into the Vault when
checking in a folder containing DXF files from outside the working
folder.
- DXF files will be checked into the Vault when checking in
a folder
containing DXF files from within the working folder. In this case, DXF
files with attachments will be checked in but all file relationships
will be lost.
Inventor References
in AutoCAD
- To check in files with model documentation drawing views, a
default Inventor project file must be set in the Vault options.
- To ensure synchronization with Vault, it is recommended
that you
set the Inventor project file in AutoCAD to be the same as the default
Inventor project file in the Vault options.
Sheet Sets and
Sheet Set Manager (SSM)
- The Check in Folder command does not support sheet sets.
- Property write-back is not supported on sheet set files.
- The Vault sheet set manager integration does not support
offline editing of sheet set files.
- The sheet set property 'Sheet set data file' cannot be
mapped as a
Vault user-defined property. Instead use the 'File Name' Vault system
property.
- Renaming a sheet set in Sheet Set Manager will not update
corresponding folder and file names in Vault, though all folders and
files will resolve correctly.
- Renaming or moving sheet set data files or folders in Vault
is not
supported and will result in Sheet Set Manager not reflecting the
changes.
- To change the Sheet Set automatic Check In visualization
attachment options:
- Exit AutoCAD.
- Open the file ‘Preferences.xml’ at
‘%appdata%\Autodesk\AutoCAD [Version] Vault AddIn\Objects’ with any
text editor.
- Under
the respective AutoCAD profile ‘CheckIn On Auto Checkin SheetSet
Options’, look for ‘<Property Name="DWF Option" Value="No DWF"
/>'.
- Replace “No DWF”, the default value, with “Create
DWF locally” to create visualization during Check In or “Create DWF
using Job Server” to send to Job Server.
Return to
Top
Inventor
Add-in Information
Inventor LT
- When using Inventor LT with Vault, the user's workspace is
preset
to %USERPROFILE%\My Documents\Vault\Designs and mapped to the root
folder “$” in Vault. The workspace mapping cannot be changed.
- If Vault add-in for Inventor LT fails to load, remove the
Inventor
LT project file "Vault_Default.ipj" from ".\users\<Current
User>\Documents\Vault" and then restart Inventor LT.
- If you desire to work with a different workspace you must
first
disable the Vault add-in. To stop working in a vaulted environment,
unload the Inventor Vault Add-In, uncheck Load Automatically for the
add-in, and restart Inventor LT. After which, the ability to change a
user's workspace will be restored.
- To load the Vault Add-In manually from the Add-in Manager,
all documents must be closed. Otherwise, the add-in will not load.
- Assembly files are not supported in Inventor LT. If an
assembly
file is opened from Vault, a warning message will not be displayed.
- Vault functionality included in Task Scheduler is disabled
in Inventor LT.
- Viewing assembly files in Vault which contain Content
Center parts
or running Pack and Go on assemblies which contain Content Center parts
will result in issues if Inventor LT was last run. If viewing an
assembly with Content Center parts the view will not load. If
attempting a Pack and Go on an assembly with Content Center parts, the
exported Inventor project file will have the Content Center path set to
[Default] and a missing file warning may be displayed upon opening the
assembly. These issues can be avoided by running Inventor View
immediately prior to either the View or Pack and Go operation.
All Vault Editions
- The Vault browser will show that a file has been edited in
memory
for iPart Factories and iAssembly Factories if any members were renamed
in Vault Explorer.
- When using substitutes, it is strongly recommended that all
data be
created within the working folder. If the data was created outside of
the working folder and then added to a Vault, it is recommended that
you open the file from Vault, Edit the file, and then save and check in
all assemblies before performing any other Vault operations.
- The Inventor Vault add-in does not support AutoCAD files
with model documentation drawing views of Inventor references.
- If opening an AutoCAD file with model documentation drawing
views
of Inventor references, the Inventor add-in will prompt more than once
to check out and update properties for the file.
- Checkout prompt is seen even before clicking 'Update'
button in Inventor assembly when the 3rd party data is modified.
- Inventor Vault browser needs explicit 'Refresh' to remove
3rd party
data when selecting 'Place Import CAD files' but without placing the
files.
- Assembly child parts may not appear in Vault Browser when
3rd party
data is 'Opened' using Inventor 'Convert model' option. Perform a Vault
Browser 'Refresh' to resolve this issue.
- The Inventor/Vault browser(s) may not appear when using a
Windows
10 dual monitor environment if the two monitors have different display
scalings (e.g. one monitor is high resolution and the other is not). If
this happens to you, attempt one of the following workarounds to
restore the Inventor/Vault browser(s):
- Change an Inventor Property
- Close Inventor
- Go to Inventor.exe > Properties >
Compatibility
- Check Disable display scaling on high DPI
settings > OK
- Relaunch Inventor and open the assembly
- The Vault tab should reappear
- Reduce the DPI settings of the higher resolution monitor
- Reduce the display scaling of the monitor with 200% DPI
scaling to 100% DPI
- The Vault browser should return
- Switch Displays
- Drag the Inventor application onto the screen with
lower resolution
- Close the assembly that's currently open
- Open the assembly or a new file and the Vault tab
should reappear near the bottom of the screen
Vault Professional
Edition Only
- While working with Vault 2019 Items created from 3rd party
files
referenced in Inventor 2016 assemblies (i.e. Inventor 2016 AnyCAD Data)
stored in Vault 2016, users must perform the following actions in Vault
2019 to properly update those Items.
- Within Inventor 2019, checkout all 3rd party files
related to the items you wish to update.
- Perform Inventor 2019 'Edit-Import' operation on all the
3rd party files, save, and check-in all files to Vault 2019.
- Administrator must setup the following Vault 2019
property mappings:
- 'Number' Property 'Initial Value' mapped to 'Part
Number' property for 'Other files'.
- 'Equivalence Value' property mapped to 'Part Number'
for 'Other Files'.
- Perform Vault 2019 ‘Update Item’ operation on each 3rd
party file.
- Detail IDs will not be created for Substitute Parts when
the master
assembly is uploaded to Vault using "Check In Project." The Update File
References command should be executed in Vault Explorer to get Detail
IDs created for Substitute Parts.
- Update Item will pull the values of the Detail ID from BOM
table and update the Position Number values.
- The Item Position Number is extracted for the root
component only for a structure BOM.
Return to
Top
Copy Design for Vault
Workgroup and Vault Professional
- The Item BOM is not updated for files created in latest
copy
design. Users must open and save files in their native application to
update the BOM detail.
- Replacing multiple files at the same assembly structure
level with a single file will result in creation of a single reference.
- There is no restriction on replace file types. Selecting
incompatible replacements may result in failure of new files.
- Any changes to Vault property settings (e.g., default
values,
mappings, enablement) are not captured in the Copy Design Rule set XML
after creation. Users must log out and log in to the copy design
application to update property behavior in the action rules.
- The new names given by the Numbering Scheme will not be
seen in the Copy Design Grid even after Copy action is done.
- Copy Design Action rules do not currently apply to Inventor
iProperty 'Estimated Cost'.
- Users may experience issues when performing copy design on
un-replicated files.
- Copy Design leverages the user-defined default Inventor
project.
Resolution errors can occur if a different project is used to open the
files after copy.
- New file relationships created during Copy Design are
repaired on
open. Users should open and update copied files before carrying out
additional work on the data.
- When making project copies with Copy Design, the user must
manually
enforce the proper naming convention of the AutoCAD Electrical
configuration files.
- Copy Design permits the copy of iParts and iAssemblies with
the following remarks:
- Factories and members may be copied together BUT there is
no
associative link between these files. New copied members will not
reflect table entries.
- Members may be copied and used as stand-alone components.
- Factories may be copied and the table edited to create
new members.
- Users must open and save files after copying in order to
break the relationship link between Factory and Member.
Return to
Top
Revit Add-in
Install Information
Revit Add-in
Information
- When loading a large number of Revit files into the Vault
server,
add files in batches of less than 1000 files, enable the Revit deep
index, and wait for the index to complete before loading the next batch
of files.
Return to
Top
Project Sync for
Vault Professional (Subscription only)
- When using Desktop Connector via Vault, if you cancel the
Log in dialog, you will have to cancel the operation and redo it.
- When
using this feature the operation will show up on the Job
Queue.
There will be no indication to the user that a task is executing or
not. To see the current status of your Job, go to the Job
Queue.
- You
must have the "Object Get Attributes" permission in order to use the
manual sync functionality. No other functionality is using
this
permission at this point in time.
Return to
Top
Vault Data Standard for
VaultWorkgroup and Vault Professional
- The Vault Data Standard needs to be uninstalled separately.
Uninstalling Vault client will not automatically uninstall Vault Data
Standard.
- The configuration settings of Inventor Addin-In are loaded
only if the add-in
loads. So there is a difference to load/unload Vault Data Standard
addin within the AddIn Manager and enable/disable Vault Data Standard
in the Vault Data Standard Ribbon.
- In
order to avoid popping up the Vault File Numbering dialog and mess up
the File numbering when saving Functional Documents (Frame Generator,
Design Accelerator etc.), please deselect “Hide extensions
for
known file types”. To change the settings, Click the Windows Start
button and then type “Folder Options” in Windows 7 (“File Explorer
Options” in Windows 10), press Enter and in the Folder
options
dialog, go to the View tab and deselect “Hide extensions for known file
types”.
- If
you click the CAD/BOM tab in the Vault Explorer preview and only zeros
are displayed, this means that the BOM view in Inventor is not enabled
for Vault. Go to the Manage tab in Inventor and open up Bill of
Materials. Right-click on the structured tab and select Enable BOM
View. The CAD/BOM preview will work now. See the Inventor Help for more
information.
- If Data Standard doesn't start properly in Vault Explorer,
restart the Vault Client.
- In
case the ribbon “Data Standard” is missing in AutoCAD or AutoCAD
Mechanical, reload the AutoCAD Customization File “MVFApartialcui.cuix”
using the AutoCAD command CUILOAD. The “MVFApartialcui.cuix” is located
in folder “C:\ProgramData\Autodesk\ApplicationPlugins\Autodesk
DataStandard 2019.bundle\Contents\Resources\en-US”
- A version of
Data Standard might appear two times in the list of installed programs
on the control panel. This happens if Data Standard is installed with
different language setups. The installation of the program is correct
and it will be working correctly.
- The tab “CAD BOM” only works
with Inventor components that are marked as “Normal” in the Inventor
CAD BOM. Other components might be missing.
Return to
Top
Autodesk Vault Professional, Autodesk Vault Workgroup, Autodesk Vault
Basic, Autodesk Data Management Server, Autodesk Vault Office, Autodesk
Inventor, AutoCAD, AutoCAD Mechanical, and AutoCAD Electrical are
trademarks of Autodesk, Inc. in the United States and/or other
countries. Windows Server 2012, Windows Server 2016, SQL Server 2014,
SQL Server 2016, SQL Server 2017, Windows 7, Windows 8.1, Windows 10,
Microsoft Office 2013 and Microsoft Office 2016 are either trademarks
or registered trademarks of Microsoft Corporation in the United States
and/or other countries. All other trademarks are the property of their
respective owners.
Return to
Top